You are here: Home » Products » Automatic control valve » Swing Check Valve

Product Detail

loading

Share to:
sharethis sharing button

Swing Check Valve

The slow closing check valve is composed of the main valve and the control pipeline of the hydraulic control valve, and the closing time of the main valve can be adjusted.It is installed at the outlet of the water pump of the building water supply system. It is mainly used to prevent the backflow of the medium and can effectively reduce the impact and noise of the water hammer.
Availability:
Quantity:
  • ST-KZ0005

  • SHSUOTEVALVE

  • 848180

1.Description.

The slow closing check valve is composed of the main valve and the control pipeline of the hydraulic control valve, and the closing time of the main valve can be adjusted.It is installed at the outlet of the water pump of the building water supply system. It is mainly used to prevent the backflow of the medium and can effectively reduce the impact and noise of the water hammer.

2.Main parts&material

No.PartMaterialChina stardard
1BODYDUCTILE IRONEN GJS-500-7
2SEATSTAINLESS STEELAISI 304
3O-RINGRUBBERNBR
4ORINGRUBBERNBR
5BOLTSSTAINLESS STEELA1
6WASHERSTAINLESS STEELA2
7COVERDUCTILE IRONEN GJS-500-7
8BUSHBRASSCuZn40Pb4
9SPRINGSTAINLESS STEELAISI 304
10NUTSTAINLESS STEELA2
11DIAPHRAGMRUBBEREPDM>NYLON
12SUPPORT RINGDUCTILE IRONEN GJS-500-7
13OBTURATORDUCTILE IRONEN GJS-500-7
14MAIN GASKETRUBBEREPDM
15SEAL RINGSTAINLESS STEELAISI304
16STEMSTAINLESS STEELAISI304
17PLUGSTAINLESS STEELAISI304
18PLUGSTAINLESS STEELAISI304
19V-PORTSTAINLESS STEELAISI304

3.Features

-Hydraulic control, no external driving force;

-Main valve has only one moving part, low failure rate;

-Diaphragm structure, no friction, high control sensitivity;

-The closing time of the main valve can be adjusted to reduce water hammer impact and noise.

4.Execution standard

Design standardCJ/T219, JB/T10674
Connection standardGB/T17241.6
Face spacing standardGB/T12221
Inspection testing standardGB/T13927

5.Technical parameters

Nominal diameterDN50~DN400(2"~16") PN16
DN50~DN300(2"~12") PN25
Nominal pressure
Operating temperature0°C~85°C
Seal test1.1PN
Shell test1.5PN
Suitable mediumWater

6.Operating principle

The slow closing check valve is composed of the main valve and control pipeline of the hydraulic control valve and is installed at the outlet of the water pump of the building water supply system.When the pump is open, the water flow gives upward thrust to the disc of the main valve, and the upper chamber of the main valve drains out to open the main valve. The opening time of the main valve can be controlled by adjusting the opening size of the ball valve on the control pipe.When the pump is closed, the upward thrust at the disc disappears, and the water flows back to fill the cavity of the main valve, so that the main valve is closed. By adjusting the opening of the ball valve on the control pipe, the closing time of the main valve can be controlled.

Previous: 
Next: 

CONTACT US

ADD :No. 369,Maoting Road, Chendun Town, Songjiang  District, Shanghai. 
PHONE : +86-15862638675
                +86-15862638675
EMAIL: corrine@suotevalve.com
              jack@suotevalve.com
QQ : 1515863517
Shanghai Suote Valve Co.,Ltd.
With years’ manufacturing experience,we now could offer more than 45 series valves and related parts......READ MORE